using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Threading.Tasks;
using System.Windows.Forms;
using System.IO.Ports;
using Newtonsoft.Json;
namespace Gidrolock_Modbus_Scanner
{
public partial class App : Form
{
public bool isAwaitingResponse = false;
public short[] res = new short[12];
SerialPort port = Modbus.port;
public int expectedLength = 0;
public byte[] latestMessage;
public Dictionary<string, string> models = new Dictionary<string, string>();
byte[] message = null;
byte[] data = null;
DateTime dateTime;
Datasheet datasheet;
#region Initialization
public App()
{
InitializeComponent();
Modbus.Init();
Modbus.ResponseReceived += OnResponseReceived;
this.UpDown_ModbusID.Value = 0;
TextBox_Log.Text = "Приложение готово к работе.";
cBoxDevice.Items.Add("Standard");
cBoxDevice.Items.Add("Inteli");
cBoxDevice.Items.Add("Premium Plus");
cBoxDevice.Items.Add("Premium");
cBoxDevice.SelectedIndex = 0;
checkboxID.Checked = false;
UpDown_ModbusID.Enabled = false;
UpDown_ModbusID.Value = 30;
UpDown_ModbusID.Minimum = 1;
UpDown_ModbusID.Maximum = 247;
models.Add("Standard", "STW485");
models.Add("Inteli", "INTELI");
models.Add("Premuim Plus", "BUP485");
models.Add("Premium", "BUP485");
/* - Version Check - */
System.Reflection.Assembly assembly = System.Reflection.Assembly.GetExecutingAssembly();
System.Diagnostics.FileVersionInfo fvi = System.Diagnostics.FileVersionInfo.GetVersionInfo(assembly.Location);
string version = fvi.FileVersion;
Console.WriteLine("Version: " + version);
Modbus.ResponseReceived += (sndr, msg) =>
{
message = msg.Message;
data = msg.Data;
};
}
void App_FormClosed(object sender, FormClosedEventArgs e)
{
port.Close();
}
void Form1_Load(object sender, EventArgs e)
{
CBox_Ports.Items.AddRange(SerialPort.GetPortNames());
if (CBox_Ports.Items.Count > 0)
CBox_Ports.SelectedIndex = 0;
}
#endregion
private async void ButtonConnect_Click(object sender, EventArgs e)
{
if (CBox_Ports.SelectedItem.ToString() == "COM1")
{
DialogResult res = MessageBox.Show("Выбран серийный порт COM1, который обычно является портом PS/2 или RS-232, не подключенным к Modbus устройству. Продолжить?", "Внимание", MessageBoxButtons.OKCancel);
if (res == DialogResult.Cancel)
return;
}
if (UpDown_ModbusID.Value == 0)
{
DialogResult res = MessageBox.Show("Указан Modbus ID 0 — глобальное вещание. Устройства не смогут отвечать на сообщения. Продолжить?", "Внимание", MessageBoxButtons.OKCancel);
if (res == DialogResult.Cancel)
return;
}
try
{
/* - Port Setup - */
if (port.IsOpen)
port.Close();
port.Handshake = Handshake.None;
port.PortName = CBox_Ports.Text;
port.BaudRate = 9600;
port.Parity = Parity.None;
port.DataBits = 8;
port.StopBits = StopBits.One;
port.ReadTimeout = 3000;
port.WriteTimeout = 3000;
port.ReadBufferSize = 8192;
port.Open();
// send read request for 6 registers starting from 200
// if we've got error or a timeout, show appropriate errors
// else parse response to unicode and go through every .json
// if matching model is found, instantiate device window
// setup event listener
// send message
AddLog("Проверка модели устройства.");
if (await PollModel())
{
Console.WriteLine("true");
// confirm the model
string response = ByteArrayToUnicode(data);
if (response != models[cBoxDevice.SelectedItem.ToString()])
{
// response doesn't match expected model
AddLog("Ответ устройства не соответствует выбранной модели. Поиск подходящей модели.");
// check whether it matches anything else, offer to open that model if it does
string match = "";
string model = "";
int index = 0;
foreach (string key in models.Keys)
{
if (models[key] == response)
{
match = models[key];
model = key;
break;
}
index++;
}
if (match == "") // if no matches found
MessageBox.Show("Подключенное устройство не соответствует ни одной из поддерживаемых моделей.");
else // match found, offer to switch to that model instead
{
DialogResult result = MessageBox.Show(("Подключенное устройство соответствует модели " + model + ". Нажмите ОК, чтобы открыть настройки для модели " + model), "Внимание", MessageBoxButtons.OKCancel);
if (result == DialogResult.OK)
{
// instantiate panel
AddLog("Открываю панель конфигурации.");
Device device = GetDevice((DeviceType)index);
StartDatasheet(device);
}
}
}
else
{
// model is correct, instantiate config panel
int index = cBoxDevice.SelectedIndex;
AddLog("Устройство соответстует модели, открываю панель конфигурации.");
Device device = GetDevice((DeviceType)index);
StartDatasheet(device);
}
}
}
catch (Exception ex)
{
MessageBox.Show(ex.Message);
}
}
async Task<bool> PollModel()
{
var send = Modbus.ReadRegAsync((byte)UpDown_ModbusID.Value, FunctionCode.ReadInput, 200, 6);
isAwaitingResponse = true;
Task<bool> delay = Task.WhenAny(Task.Delay(2000), Task.Run(() => { while (isAwaitingResponse) { } return true; })).ContinueWith((t) =>
{
if (isAwaitingResponse)
{
Console.WriteLine("Response timed out.");
isAwaitingResponse = false;
}
return false;
});
return await delay;
}
void StartDatasheet(Device device)
{
datasheet = new Datasheet((byte)UpDown_ModbusID.Value, device);
datasheet.Show();
}
void CBox_Ports_Click(object sender, EventArgs e)
{
CBox_Ports.Items.Clear();
CBox_Ports.Items.AddRange(SerialPort.GetPortNames());
}
void OnResponseReceived(object sender, ModbusResponseEventArgs e)
{
isAwaitingResponse = false;
AddLog("Получен ответ: " + Modbus.ByteArrayToString(e.Message));
switch (e.Status)
{
case (ModbusStatus.ReadSuccess):
string values = "";
if (e.Message[1] <= 0x02)
{
for (int i = 0; i < e.Data.Length; i++)
{
values += Convert.ToString(e.Data[i], 2).PadLeft(8, '0') + " ";
}
AddLog("Bin: " + values);
}
if (e.Message[1] == 0x03 || e.Message[1] == 0x04)
{
for (int i = 0; i < e.Data.Length; i += 2)
{
values += ((e.Data[i] << 8) + e.Data[i + 1]).ToString() + "; ";
}
AddLog("Dec: " + values);
AddLog("Unicode: " + ByteArrayToUnicode(e.Data));
}
break;
case (ModbusStatus.WriteSuccess):
AddLog("Write success;");
break;
case (ModbusStatus.Error):
string errorDesc;
switch (e.Message[2])
{
case (0x01):
errorDesc = "01 - Illegal Function";
break;
case (0x02):
errorDesc = "02 - Illegal Data Address";
break;
case (0x03):
errorDesc = "03 - Illegal Data Value";
break;
case (0x04):
errorDesc = "04 - Slave Device Failure";
break;
case (0x05):
errorDesc = "05 - Acknowledge";
break;
case (0x06):
errorDesc = "06 - Slave Device Busy";
break;
case (0x07):
errorDesc = "07 - Negative Acknowledge";
break;
case (0x08):
errorDesc = "08 - Memory Parity Error";
break;
case (0x0A):
errorDesc = "10 - Gateway Path Unavailable";
break;
case (0x0B):
errorDesc = "11 - Gateway Target Device Failed to Respond";
break;
default:
errorDesc = "Unknown error code";
break;
}
AddLog("Error code: " + errorDesc);
break;
}
}
void AddLog(string message)
{
dateTime = DateTime.Now;
TextBox_Log.Invoke((MethodInvoker)delegate { TextBox_Log.AppendText(Environment.NewLine + "[" + dateTime.Hour.ToString().PadLeft(2, '0') + ":" + dateTime.Minute.ToString().PadLeft(2, '0') + ":" + dateTime.Second.ToString().PadLeft(2, '0') + "] " + message); });
}
public static string ByteArrayToUnicode(byte[] input)
{
// stupid fucking WinForm textbox breaks from null symbols
// stupid fucking Encoding class does byte-by-byte conversion
List<char> result = new List<char>(input.Length / 2);
byte[] flip = input;
Array.Reverse(flip); // stupid fucking BitConverter is little-endian and spits out chinese nonsense otherwise
for (int i = 0; i < flip.Length; i += 2)
{
result.Add(BitConverter.ToChar(flip, i));
}
result.Reverse();
return new string(result.ToArray());
}
private void checkboxID_CheckedChanged(object sender, EventArgs e)
{
UpDown_ModbusID.Enabled = checkboxID.Checked ? true : false;
}
private void cBoxDevice_SelectedIndexChanged(object sender, EventArgs e)
{
switch (cBoxDevice.SelectedItem)
{
case "Standard":
UpDown_ModbusID.Value = 30;
break;
case "Premium Plus":
UpDown_ModbusID.Value = 30;
break;
case "Inteli":
UpDown_ModbusID.Value = 26;
break;
case "Premium":
UpDown_ModbusID.Value = 26;
break;
default:
Console.WriteLine("Invalid change");
break;
}
}
public Device GetDevice(DeviceType dt)
{
Device d = new Device();
switch (dt)
{
case DeviceType.Standard:
d.modelName = "Standard";
d.name = "Gidrolock Standard Wi-Fi RS485";
d.id = 30;
d.modelName = "STW485";
d.valveStatus = new Entry(RegisterType.Coil, 1202);
d.alarmStatus = new Entry(RegisterType.Coil, 1201);
d.hasCleaningMode = true;
d.cleaningMode = new Entry(RegisterType.Coil, 3);
d.hasBattery = false;
d.wiredSensors = 2;
d.hasScenarioSensor = true;
d.sensorsAlarm = new Entry(RegisterType.Discrete, 1343, 24);
d.radioStatus = new Entry(RegisterType.Input, 1215, 21);
break;
case DeviceType.Inteli:
d.modelName = "Inteli";
break;
case DeviceType.PremiumPlus:
d.modelName = "Premium Plus";
break;
case DeviceType.Premium:
d.modelName = "Premium";
break;
default:
break;
}
return d;
}
}
}
public enum FunctionCode { ReadCoil = 1, ReadDiscrete = 2, ReadHolding = 3, ReadInput = 4, WriteCoil = 5, WriteRegister = 6, WriteMultCoils = 15, WriteMultRegisters = 16 };
//public enum SelectedPath { File, Folder };
public enum DeviceType { Standard, Inteli, PremiumPlus, Premium };