32 lines
1.0 KiB
Markdown
32 lines
1.0 KiB
Markdown
# ZigBee2MQTT: config files
|
|
Extension files for ZigBee2MQTT; only one of the files is required for device support.
|
|
Extract the file into the `/data` folder. Add the following lines to `configuration.yaml` file in the same folder:
|
|
```
|
|
external_converters:
|
|
- Winner_ZigBee_Basic.js
|
|
```
|
|
|
|
## Winner_ZigBee_Basic.js
|
|
Basic support for Winner. Available fields:
|
|
- Valve position: open/closed
|
|
- Alarm status
|
|
- Because of the device's firmware, you cannot turn the alarm on
|
|
- Cleaning mode status
|
|
- Battery charge level
|
|
- Error code
|
|
|
|
## Winner_ZigBee_dev.js
|
|
**Works the same way as Basic version.**
|
|
|
|
A version with the full list of the device DPs. Additional DPs will not work with Z2MQTT because of their non-standard implementation: you would need to write additional code for Z2MQTT libraries to properly parse the incoming data.
|
|
|
|
E.g: any `sensor_*` DP is a 4 byte integer:
|
|
```
|
|
0xAA_BB_CC_DD where:
|
|
[AA] - command bit flags
|
|
[BB] - status bit flags
|
|
[CC] - signal strength
|
|
[DD] - battery charge
|
|
```
|
|
This will not be parsed accordingly right out of the box.
|